Point β sources

#{name}

Radionuclides are deposited between two hot-sealed polyester foils (approximately 75μm thick each). Each face of the source is gold vacuum-coated for optimum measurement efficiency. They are then mounted in a steel ring.

 

Radiological characteristics of the sources are measured with a calibrated gas flow proportional counter.

#{name}
Source beta EBSA
Source beta EBSB
Source beta EBSC
Source beta EBSA © LEA - Cyril Crespeau Source beta EBSB © LEA - Cyril Crespeau Source beta EBSC © LEA - Cyril Crespeau
#{name}

Catalog references

On request

Active diameter

3 mm Ÿ 0.12 in

From 3 to 30 mm

From 0.12 to 1.2 in

30 mm Ÿ 1.2 in

External diameter

25 mm Ÿ 1 in

From 25 to 60 mm

From 1 to 2.4 in

38 mm Ÿ 1.5 in

50 mm Ÿ 2 in

Activity

0.08 kBq Ÿ 0.002 µCi

From 0.05 to 30 kBq

From 0.001 to 8.1 µCi

3 kBq Ÿ 0.08 µCi

Radionuclide

22Na, 36Cl, 60Co, 90Sr/90Y, 137Cs/137mBa, 147Pm, 204Tl, 89Sr, 134Cs

32P, 35S, 45Ca, 63Ni, 99Tc, 129I

Radionuclide

4π sr beta flux

k=2 measurement uncertainty

Equivalent activity

Reference

 
 

Under COFRAC* accreditation

 

36Cl

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

CL36 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

CL36 EBS [Type] 30

 

60Co

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

CO60 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

CO60 EBS [Type] 30

 

134Cs

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

CS134 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

CS134 EBS [Type] 30

 

137Cs

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

CS137 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

CS137 EBS [Type] 30

 

22Na

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

NA22 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

NA22 EBS [Type] 30

 

147Pm

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

PM147 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

PM147 EBS [Type] 30

 

89Sr

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

SR89 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

SR89 EBS [Type] 30

 

90Sr + 90Y

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

SR90 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

SR90 EBS [Type] 30

 

204Tl

80

β.s-1

≤ 1.5%

0.08 kBq • 0.002 µCi

TL204 EBS [Type] 20

 

3 000

β.s-1

≤ 1.5%

3 kBq • 0.08 µCi

TL204 EBS [Type] 30

 
       

Standard manufacturing tolerance: ± 30%  

IAEA Category : 5 • ISO2919 Classification: C11111

How to compose the reference ? 

Replace [Type] with the letter A, B or C according to the required geometry. For example: TL204 EBS A 30.

 

* Scope N°2-6386 available on www.cofrac.fr or upon request.

 
#{name}

EBS A and EBS B sources are also available in kit form. Radionuclides supplied are 147Pm, 134Cs, 137Cs, 90Sr+90Y, 204Tl and 22Na with an activity of 0.002 μCi (80 Bq) or 0.08 μCi (3 000 Bq). Other activities of EBS sources are available on request.

Coffret Bêta (1) © LEA - Cyril Crespeau

LEAContact

See more
By clicking “I accept Cookies”, you agree with the cookies use to enhance site navigation, analyze site usage and compile statistics. To get more information, please read our Cookies Policy in the Legal Notice